INSTRUCTION MANUAL
FOR
RECLOSING RELAY
BE1-79A
Part Number: 9310200114
Publication: 9310200893
Revision: C 09/14
Reset
Serial Port
Power
Reset
Sequence
Lockout
In
Reclosing
Relay
BE1-79A
SENSING INPUT RANGE:
48/250VDC 120/240VAC
POWER SUPPLY: 125/250V AC/DC
ITEM NUMBER: 9310200114
SERIAL NUMBER: ***** REV **
PATENT 6,239,960
Vista de página 0
1 2 3 4 5 6 ... 61 62

Resumo do Conteúdo

Página 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL FOR RECLOSING RELAY BE1-79A Part Number: 9310200114 Publication: 9310200893 Revision: C 09/14 ResetSerial PortPowerResetSe

Página 2

ii BE1-79A General Information 9310200893 Rev C

Página 3 - INTRODUCTION

SECTION 1 • GENERAL INFORMATION Description The BE1-79A Reclosing Relay is an economical, microprocessor-based relay that automatically recloses circu

Página 4 - HIGHLAND IL 62249 USA

Reset Timers 1, 2, 3, 4, and Final Range ... 0 to 300 seconds Increments ...

Página 5 - REVISION HISTORY

Type Tests Electrostatic Discharge (ESD) 8 kV contact discharges and 15 kV air discharges applied in accordance with IEC 801-2 ESD. Dielectric Strengt

Página 6

1-4 BE1-79A General Information 9310200893 Rev C

Página 7 - CONTENTS

SECTION 2 • CONTROLS AND INDICATORS TABLE OF CONTENTS SECTION 2 • CONTROLS AND INDICATORS ...

Página 8

ii BE1-79A Controls and Indicators 9310200893 Rev C

Página 9

SECTION 2 • CONTROLS AND INDICATORS Front Panel Front panel controls and indicators are illustrated in Figure 2-1 and described in Table 2-1. The loca

Página 10

Table 2-1. Front Panel Control and Indicator Descriptions Locator Description A Power LED. A lit Power LED indicates that operating power is applied t

Página 11 - Specifications

SECTION 3 • FUNCTIONAL DESCRIPTION TABLE OF CONTENTS SECTION 3 • FUNCTIONAL DESCRIPTION ...

Página 13 - Maintenance

ii BE1-79A Functional Description 9310200893 Rev C

Página 14

SECTION 3 • FUNCTIONAL DESCRIPTION Introduction BE1-79A relays are microprocessor-based devices that provide automatic reclosing of circuit breakers.

Página 15 - TABLE OF CONTENTS

Operating Power Operating power for the internal circuitry is applied to the internal, isolated, switching power supply. The power supply operates ove

Página 16

Microprocessor All reclosing and communication functions are coordinated by the microprocessor. The BE1-79A uses an eight-bit microprocessor with inte

Página 17 - Front Panel

Interconnections Figure 3-2 illustrates the interconnection of the contact sensing inputs, relay outputs, style configuration switches, instantaneous

Página 18

Recloser Operation Information about the software-controlled features of the recloser is provided in the following paragraphs. Reset A reclosing seque

Página 19

Figure 3-3. Reclose Settings Example Time zero begins at 1st breaker opening.Final Reset= 185 s or 5 s after manual closeReclose 1= 10 s10 s20 s 20

Página 20

Figure 3-4. Reclosing Flow Chart Reset 2Time?ResetRec 4Time?52B?Rec. 1Time?52B?Issue RecloseSignal52B?RecloseComplete?Reset 1Time?52A?ResetResetCom

Página 21 - Introduction

3-8 BE1-79A Functional Description 9310200893 Rev C

Página 22 - Serial Communication Port

SECTION 4 • COMMUNICATION COMMANDS TABLE OF CONTENTS SECTION 4 • COMMUNICATION COMMANDS ...

Página 23 - Fault Clearing

INTRODUCTION This instruction manual provides information about the operation and installation of the BE1-79A Reclosing Relay. To accomplish this, the

Página 24 - Interconnections

ii BE1-79A Communication Commands 9310200893 Rev C

Página 25 - Recloser Operation

SECTION 4 • COMMUNICATION COMMANDS Introduction Communication commands are sent to the BE1-79A through a standard RS-232 (DB-9) connector located on t

Página 26 - Relay Settings

items. For example, the SP-79A1 command could be used to read the first reclose setting or the command S could be used to read all reclose settings. C

Página 27

For clarity in the examples, relay responses are printed in the Courier typeface. EXIT command example: exit after making setting changes. EXIT >SA

Página 28

Lockout Timer Setting Command SP-79ALO Command Purpose: Read or change the lockout timer settings. Syntax: SP-79ALO[=<lockout time delay>,<

Página 29

SECTION 5 • INSTALLATION AND CONFIGURATION TABLE OF CONTENTS SECTION 5 • INSTALLATION AND CONFIGURATION ...

Página 30

ii BE1-79A Installation and Configuration 9310200893 Rev C

Página 31 - ASCII Command Format

SECTION 5 • INSTALLATION AND CONFIGURATION General BE1-79A Reclosing Relays are delivered in sturdy cartons to prevent shipping damage. Upon receipt o

Página 32 - Command Descriptions

Figure 5-1. Typical AC Application Connections 5-2 BE1-79A Installation and Configuration 9310200893 Rev C

Página 33

Figure 5-2. Typical DC Application Connections 9310200893 Rev C BE1-79A Installation and Configuration 5-3

Página 34 - Relay Information Command

First Printing: October 2011 Printed in USA Copyright © 2014 Basler Electric, Highland Illinois 62249 USA All Rights Reserved September 2014 CO

Página 35 - CONFIGURATION

Motor Voltage No adjustment is required for the voltage applied at terminals 2 and 8. The applied voltage can range from 120 to 240 Vac or 125 to 250

Página 36

Figure 5-3. Contact Sensing Jumper Locations and Positions Relay Installation Perform the following procedure to install the BE1-79A relay. 1. Inser

Página 37

Communication Connections and Settings The required connections and settings for BE1-79A communication are described in the following paragraphs. Comm

Página 38

SECTION 6 • TESTING TABLE OF CONTENTS SECTION 6 • TESTING ...

Página 39

ii BE1-79A Testing 9310200893 Rev C

Página 40 - Motor Voltage

SECTION 6 • TESTING Introduction You may prefer to test your relay before installation. To test BE1-79A relay functionality, perform the procedures in

Página 41 - Relay Installation

Delayed Reclose Testing 1. Place Test switch S1 in the 52a position and apply 120 Vac to the relay and test circuit. 2. Connect a PC with a serial p

Página 42 - Communication Settings

Figure 6-1. Test Connections LockoutS152a52b120 Vac367911121314151617181920P0064-8528L4RSL5552a452b110LockoutRSClose #3Close #2Close #1Reclose #1L

Página 43 - SECTION 6 • TESTING

Troubleshooting Tips The front panel LED indicators will annunciate certain conditions that will inhibit the BE1-79A relay from providing reclose prot

Página 44

APPENDIX A • RS CONTACT APPLICATION TABLE OF CONTENTS APPENDIX A • RS CONTACT APPLICATION ...

Página 45

REVISION HISTORY The following information provides a historical summary of the changes made to this instruction manual (9310200893), application firm

Página 46 - Delayed Reclose Testing

ii BE1-79A RS Contact Application 9310200893 Rev C

Página 47 - Figure 6-1. Test Connections

APPENDIX A • RS CONTACT APPLICATION Introduction The RS contact can be applied to disable the instantaneous trip circuit of protection relays after an

Página 48 - Troubleshooting Tips

RS Contact Settings The RS contact setting command, SP-79ARS, determines the mode, apply time, and remove time of the RS contact. SP-79ARS command syn

Página 49

Figure A-1. RS Contact Setting Examples Time zero begins at 1st breaker opening.Final Reset= 185 s or 5 s after manual closeReclose 1= 10 s10 s20 s

Página 50

A-4 BE1-79A RS Contact Application 9310200893 Rev C

Página 51 - RS Contact Output State

APPENDIX B • TERMINAL COMMUNICATION TABLE OF CONTENTS APPENDIX B • TERMINAL COMMUNICATION ...

Página 52 - RS Contact Settings

ii BE1-79A Terminal Communication 9310200893 Rev C

Página 53 - 09-20-05

APPENDIX B • TERMINAL COMMUNICATION Windows® 2000/XP HyperTerminal (provided with Windows® 2000/XP) or other stand-alone software can be used to co

Página 54

Figure B-2. Connect To Dialog Box Step 6: Dialog Box: COMx Properties a. Make the following selections using Figure B-3 as a guide: Set the bits p

Página 55

Step 7: Click File/Properties on the menu bar. Click the Settings tab. a. Make the following selections using Figure B-5 as a guide: Check the Termi

Página 56

iv BE1-79A Introduction 9310200893 Rev C

Página 57 - Windows® 2000/XP

Figure B-5. ASCII Setup Dialog Box Step 9: HyperTerminal is now ready to communicate with the relay. Table B-1 describes the required connection f

Página 59

12570 State Route 143 Highland IL 62249-1074 USA Tel: +1 618.654.2341 Fax: +1 618.654.2351 email: [email protected] P.A.E. Les Pins 67319 Wasselonne

Página 60

CONTENTS SECTION 1 • GENERAL INFORMATION ... 1-1 SECTION

Página 61

vi BE1-79A Introduction 9310200893 Rev C

Página 62

SECTION 1 • GENERAL INFORMATION TABLE OF CONTENTS SECTION 1 • GENERAL INFORMATION ..................