DEVICE PROFILE DOCUMENT
Timeouts while waiting for:
Data Link Confirm None Fixed at 3000 ms Variable Configurable
Complete Appl. Fragment None Fixed at Variable Configurable
Application Confirm None Fixed at 5000 ms Variable Configurable
Complete Appl. Response None Fixed at Variable Configurable
Sends/Executes Control Operations:
WRITE Binary Outputs Never Always Sometimes Configurable
SELECT/OPERATE Never Always Sometimes Configurable
DIRECT OPERATE Never Always Sometimes Configurable
DIRECT OPERATE - NO ACK Never Always Sometimes Configurable
Count > 1 Never Always Sometimes Configurable
Pulse On Never Always Sometimes Configurable
Pulse Off Never Always Sometimes Configurable
Latch On Never Always Sometimes Configurable
Latch Off Never Always Sometimes Configurable
Queue Never Always Sometimes Configurable
Clear Queue Never Always Sometimes Configurable
Reports Binary Input Change Events when no
specific variation requested (Slave Only):
Never
Only time-tagged
Only non-time-tagged
Configurable to send both, one or the other
(attach explanation)
Reports time-tagged Binary Input Change Events
when no specific variation requested:
Never
Binary Input Change With Time
Binary Input Change With Relative Time
Configurable (attach explanation)
Master Expects Binary Input Change Events:
Never
Either time-tagged or non-time-tagged for a single event
Both time-tagged and non-time-tagged for a single event
Configurable (attach explanation)
Sends Unsolicited Responses
(Slave Only):
Never
Configurable (attach explanation)
Only certain objects
Sometimes (attach explanation)
ENABLE/DISABLE UNSOLICITED
Function codes supported
Sends Static Data in Unsolicited Responses
(Slave Only):
Never
When Device Restarts
When Status Flags Change
No other options are permitted.
Default Counter Object/Variation:
No Counters Reported
Configurable (attach explanation)
Default Object
Default Variation
Point-by-point list attached
Counters Roll Over at:
No Counters Reported
Configurable (attach explanation)
16 Bits
32 Bits
Other Value:
Point- by-point list attached
Sends Multi-Fragment Responses (Slave Only): Yes No